Coolant Temp Sensor Code

Discussion in 'Technical' started by Chilledpain, Jun 19, 2011.

  1. Chilledpain

    Chilledpain Z Reaper

    Hey all,

    Having a bit of an issue with the silver zed at the moment... Throwing code "Coolant Temp sensor circuit"

    Thermo fan kicks in as soon as i turn the key... I have tried the following:

    New sensor (both)
    New connector (2 wire unit)
    New ECU

    ECU still reading the correct temp but throwing a code :(

    Just wondering if anyone has any suggestions other than splicing into the ecu wires and re-running new temp connector cable?

    Any and all feedback welcome :)
     
  2. ZDUCTIV

    ZDUCTIV Active Member

    Just to confirm you are getting a code 13?

    Before running new cable I'd check for continuity between temp sensor and ECU.

    Also remember you have to clear the codes by disconnecting battery for a while or using consult to do so.
     
  3. Chilledpain

    Chilledpain Z Reaper

    Yup, code 13...

    Codes will stay present but will say how many starts ago when using conzult. In this case, it pops up with 0 starts ago. ie: Once the problem is fixed, it should say 1,2,3,4 and so on starts ago.

    Havent checked for continuity, but weird thing is the the ECU is getting a correct temp reading from the CTS yes still throwing a code 13?

    Hmmmmm!
     
  4. zed4life (zedcare.com)

    zed4life (zedcare.com) Ω vicarious zedder Ω

    To rule out the loom

    as the culprit, consider rigging up a temporary separate twin-core wire from ECU to a new CTS plug. Will cost you all of $10-15 or less in parts. My money is on a short in the loom somewhere.
     